LEAK ALERT 73 - Compact sensor for dust measurement

You are here:Home · Products · LEAK ALERT 73 - Compact sensor for dust measurement
 

LEAK ALERT 73 -
compact sensor for dust measurement

LEAK ALERT 73 is a compact sensor for electrodynamic
filter damage and leakage monitoring in industrial filter systems

  • 3 status-LEDs
  • internal display and internal set up keys for service purposes
  • flue-gas temperature up to 250 °C (400 °C option)
  • for applications up to 95 %, non-condensing,
    relative humidity (with optional insulated rod)
  • compact sensor with isolated 4 ... 20 mA-output
  • for aggressive flue-gas (with optional insulated rod)

What do you want to do?

Use

LEAK ALERT 73 is used in an industrial environment in order to carry out continuous trend measurement on clear gas sides after dust filters. Of course, the LEAK ALERT 73 can also be used for pure filter break detection. With the option of calibrating the device and providing a real volume signal (mg/m³), this compact system can in principle cover all measurement tasks, which do not have to meet official requirements.

LEAK ALERT 73 is used for:

  • Trendmonitoring (4 … 20 mA)
  • Quantity measurement of dust (mg/m³)

Function

LEAK ALERT 73 uses the electrodynamic measurement principle. If the dust to be measured is constant, then the generated measuring signal is proportional to the dust concentration, even if there are dust deposits on the measuring probe. Experience shows that the measuring method provides very exact results with little required maintenance.

A complete measuring system consists of these components:

  • Welded casing to serve as a sensor receptacle
  • LEAK ALERT 73-sensor

Technical Data

Sensor Ambient Air Temperature -25 ... +55 °C
  Stack Gas Temperature 250 °C standard or 400 °C option
  Stack Connection 1½ BSP
  Enclosure Rating IP 65
  Power Requirements 100 ... 24 V AC or 24 V DC
  Outputs (Standard)



Optional
4 ... 20 mA (500 Ω)
Warning alarm relay (SPST 1 A @ 24 V DC)
Emission alarm relay (SPST 1 A @ 24 V DC)

RS 232 ModBus
Rs 485 ModBus - enables use of PC-ME Dust Tools PC software suite
  Inputs Plant stop signal (output to zero when plant is off)
marker for start of bag cleaning sequence
  External LEDs x3) 1 Power / sensor OK
2 Warning and limit alarm
3 Self check status (options)
  User Set Up 4 digit display and set up buttons (external keypad and display option)
  Cable Entries 3 x M20 gland/conduit entries
  Air purge Connection Optional air purge fitting is required, ¼ BSP connection to instrument air line
     
     
 
 