QAL 360 - Optical dust emission measurement and monitoring

You are here:Home · Products · QAL 360 - Optical dust emission measurement and monitoring
 

QAL 360 -
Optical dust emission measurement
and monitoring

Optical, continuous measurement and monitoring
of dust emissions according to QAL1

  • backscatter device
  • certified according to QAL1 with regard to standards EN 14181
    and EN 13284-2 as well as EN 15267-3, additional TÜV approved
    according to 13., 17., 27. and 30. BImSchV (latest version)
  • automatic zero-, span- and contamination-check to fulfill QAL3-requirement
  • automatic, integrated compensation of dust deposits on the sensor
  • "PCME ProController“ for up to 32 sensors
  • reduction of material-, downtime- and maintenance costs
  • flue-gas temperatures up to 250 °C (optional 400 °C)
  • measuring range: <1 - 500 mg/m3
  • certified measuring range: 0 - 7,5 mg/m3
  • stack diameter: 1 m - 10 m
  • digital inputs and outputs
  • external connections: RS 485 or ethernet (optional)
  • simple installation (no remote station necessary)
  • low maintenance requirements

What do you want to do?

Technical data

Sensor Ambient air temperature -20 ... +50 °C
  Stack gas temperature -20 ... +250 °C standard
  Stack connection 3" 150 Ib ANSI
DN 80 PN 10/PN 16
JIS 100-5k, -10k
  Enclosure rating IP 65
  Power requirements 100 - 240 V AC or 24 V DC
  Cable entries 3 x M20
  Air purge connection Optional, standard for high temperature sensors
Transmitter Outputs 4 x 4 ... 20 mA (500 Ω)
a1x RS 485 (ModBus RTU)
4 x relais (2 A @ 250 V)
  Inputs Plant stop signal
Cleaning andmultiple calibration
  Emission data logs Capacity stated for 4 sensors with QAL3
3 months @ 15 min
7 days @ 1 minute
2 hours @ 1 second
  Enclosure size 263 x 160 x 91 mm
  Power supply 90 ... 260 VAC, 1 A
 
 

Quickfinder: What are you searching?